Backing up and versioning motor-drive parameters

Link parameter files to machine and motor identity for recovery after drive replacement or fault.

Link parameter files to machine and motor identity for recovery after drive replacement or fault.

01 /

Identify the machine for each backup

Store drive model, firmware, motor code and date with the file. Verify it can be read by the device.

02 /

Repeat motion tests after a change

Loading parameters is not commissioning. Check direction, limits, brake, speed and stop behavior under the right procedure.